AC Contactor

  • CJX2-K(LC1-K) Series AC Contactors

    CJX2-K(LC1-K) Series AC Contactors

     

    Application:  

    CJX2-K series AC contactor is suitable for use in the circuit up to the rate and frequent starting, controlling the AC motor. The addition of auxiliary contact group to the contactor, combined with the proper thermal relay, can act to protect the circuit bound to overload. It conforms to 1EC60947-4-1.

     

    Normal Running And Installtion Conditions:

    1. Ambient air temperature: -5℃+40℃. the average value should not exceed +35℃ within 24 hours
    2. Elevation: at most 2000m.
    3. Atmospheric conditions: When the temperature at 40℃,the relative humidity of atomsphere should be at the most 50%.When at relatively low temperatures, it could have higher relative humidity.Monthly maximum relative humidity could be not more than 90%.Special measures should be taken due to occurrence of dews.
    4. Class of pollution:Class 3
    5. Installation category: Ⅲ
    6. Installation conditions: Degree of inclination between fitting surface and vertical surface should not exceed II
    7. Impact shock: Product should be installed and used in the place where often shakes and impacts.

  • CJX2-F Series AC Contactor

    CJX2-F Series AC Contactor

     

    Application:  

    CJX2-Fseries AC contractor(hereinafter abbreviate to contactor)is designed for makingand breaking in main circuit, frequently starting and controlling AC motor in the power systemwith frequency of AC 50 Hz(or 60 Hz), if equipped with special coil, the frequency can be40~400Hz, rated operating voltage up to 630v, It can be used in various electrical equipment,electromotor and circuit control if assembled with appropriate reply or other general electricalappliance. In addition, it can work as mechanical interlock contactor equipped with auxiliarycontactor group, air delay head and mechanical interlock, or electromagnetic starter withappropriate thermal relay.

     

  • LA1-D series auxiliary contact blocks

    LA1-D series auxiliary contact blocks

    Application

    LA1-D series auxiliary contact blocks are installed on the top of CA2-D control relay LC1-K orLC1-D AC contactor respectively for expanding the couples of auxiliary contacts points. Owingto adopting the contacting functions of sliding frictions, the time can be self-cleaning & ensurethe electric circuit to be reliable.

    LA2-D delay timer is applicable to be LC1-D AC contactor & LA1-DN Auxiliary contact block into LC3-D star-delta reduced voltage starter is to start motor.

     

     

  • CJX2-K(LC1-K)Series AC Contactor Series

    CJX2-K(LC1-K)Series AC Contactor Series

     

     

     

    CJX2-K series AC contactors are suitable for circuits and frequent starting speeds to control AC motors. Increase the auxiliary contact group of the contactor, live with a suitable thermal relay, and can take action to protect the circuit from overload. It complies with IEC60947-4-1

  • CJX2-D series AC contactor

    CJX2-D series AC contactor

    Application

    CJX2-D series AC contactor is suitable for using in the circuits up to the rated voltage 660V AC 50Hz or 60Hz,rated current up to 660A, for making,breaking,frequently starting & controlling the AC motor, combined with the auxiliary contact block, timer delay & machine-interlicking device etc ,it becomes the delay contactor,mechanical interlocking contactor,star-edlta starter.with the thermal relay,it is combined into the electromagnetic starter.

     

    Specification

    图片1

     

     

    Dimension & Mounting Size

    图片2

  • 20-40 FLA 1p/2p AC AIR CONDITIONING CONTACTOR

    20-40 FLA 1p/2p AC AIR CONDITIONING CONTACTOR

    Application

    Air conditioning contactors(hereinafter referred to as contactors), mainly applicable to 50Hz or 60Hz, with class rated operating voltage at AC-8a
    The rated current at 240V or 277V to 40A circuit is suitable for starting and controlling single- phase AC Motors(compressors) and other single-phase loads.
    Mainly used in the household appliance industry, especially in the air-conditioning industry. Can replace the same kind of foreign imports and domestic traditional products,
    Meet IEC 60947 . 4, UL508 and GB 14048 .4 standards.

    Features 

    1.Low VA coil for cooler operation and increased life.
    2.Quiet operation.
    3.Universal style mounting bracket existing mounting holes.
    4.Double brake contacts ensure positive make and break.
    5.Screw terminal or pressure connectors and double 1/4 quick connects.
    6.Provided on all models for easy installation.

     

  • 50-90 FLA Air Conditioning Ac Contactor

    50-90 FLA Air Conditioning Ac Contactor

    Application

    Air conditioning contactors(hereinafter referred to as contactors), mainly applicable to 50Hz or 60Hz, with class rated operating voltage at AC-8a
    The rated current at 240V or 277V to 40A circuit is suitable for starting and controlling single- phase AC Motors(compressors) and other single-phase loads.
    Mainly used in the household appliance industry, especially in the air-conditioning industry. Can replace the same kind of foreign imports and domestic traditional products,
    Meet IEC 60947 . 4, UL508 and GB 14048 .4 standards.

     

     

     

  • Air conditioner ac contactor

    Air conditioner ac contactor

    LC1-D Series AC Contactor is suitable for using in the circuits up to the rated voltage 660v, AC 50hz/60hz,rated current up to 95A,for making ,breaking frequently starting &machine-interlocking device etc,it becomes the dalay contactor,mechanical interlocking contactor,star-delta starter.with the thermal relay,it is combined into the electromagnetic starter.

  • CT Series Household  contactor

    CT Series Household contactor

    Application

    CT Series Household AC Contactors are suitable for using in the circuits up to the rated voltage 400V AC 50Hz or 60Hz, rated current up to 63A, for controlling household appliances & similar usages’ low micro – load, also controlling household motors’ loading, whose controlling power shall be reduced, The products are used for family, hotel, apartment etc. places, And, it can be realized automatic function, The product conforms to GB17885, IEC61095, EN61095 standards.

  • JMC Series Ac Contactor

    JMC Series Ac Contactor

    Application

    JMC(GMC)series AC Contactor is suitable for using in the circuits up to the rated voltage 660VAC 50Hz or 60Hz,rated current up to 95A, for making,breaking,  frequently starting & machine-interlocking device etc,it becomes the delay contactor, mechanical inter-loking contactor, star-delta starter. with the thermal overload relay, it is combined into the electromagnetic starter. The contactor is produced according to IEC60947-4.

     

     

  • New CJX2-D09-D95

    New CJX2-D09-D95

    Application

    CJX2-D series AC contactor is suitable for using in the circuits up to the rated voltage 660V AC 50Hz kr 60Hz,rated current up to 660A, for making,breaking,frequently starting & controlling the AC motor, combined with the auxiliary contact block, timer delay & machine-interlicking device etc,it becomes the delay contactor,mechanical interlocking contactor,star-edlta starter.with the thermal relay,it is combined into the electromagnetic starter。

  • CJX2-D(LC1-D) Series Ac Contactor

    CJX2-D(LC1-D) Series Ac Contactor

    Application

    CJX2-D series AC contactor is suitable for using in the circuits up to the rated voltage 660V AC 50Hz kr 60Hz,rated current up to 660A, for making,breaking,frequently starting & controlling the AC motor. combined with the auxiliary contact block, timer delay & machine-interlicking device etc,it becomes the delay contactor,mechanical interlocking contactor,star-edlta starter.with the thermal relay,it is combined into the electromagnetic starter